Pairing Of Nea Smart 2.0 Room Units - Rehau NEA SMART 2.0 Service Manual

Hide thumbs Also See for NEA SMART 2.0:
Table of Contents

Advertisement

7.4.3

Pairing of NEA SMART 2.0 Room units

Note:
The below listed pairing functions are only available
in the first 48 hours after the room unit / room probe
is powered. This 48 hour time span starts again if
the room unit/ room probe gets unpowered and repowered
again. See chapter 7.4.6 for detals.
To pair a NEA SMART 2.0 Room unit:
For wireless room units (with display):
8
< 1 sec
- Insert the batteries
- Close cover
- Press Home button
12
For pairing the next units, move
with the < and > keys to the next
channel you want to pair and
perform the steps describe above.
When pairing failed, the display shows the radio wave symbol and an
exclamation mark.
In this case:
- Verify, that the Base was still in pairing mode
- Check whether the distance between room unit and NEA SMART
2.0 Base is not too big or
- Whether there are shielding elements between room unit and base
which avoid communication.
In this case whether another place for the room unit can be used.
9
> 3 sec
The room unit shows first the start
up sequence and then the radio wa-
ves and a tool symbol
13
<
OK
>
< 3 sec
To leave the pairing mode, press OK
button of the NEA SMART 2.0 Base
again for 3 secs
10
After successful pairing, the display
shows as a confirmation a hook and
then the numbers of the paired chan-
nels are shown
Note:
If the batteries have been already inserted for a longer time, press OK
for about 3 seconds to start the pairing process.
For wired room units (with display):
Press OK for less than a second to start the pairing process.
The reaction of the wired room unit is exactly the same as for wireless
room units.
11
RZ1
RZ2
RZ3
On the NEA SMART 2.0 Base, blin-
king of the paired channels changes
to a slower blinking
53

Advertisement

Table of Contents
loading

Table of Contents