7.4

Pairing

7.4.1

General notes

Pairing is the logical connection of a room unit, a
room probe or an outdoor sensor to one or more
channels of the NEA SMART 2.0 Base.
Note:
It is possible, to pair a device to one or more channels,
but it is not possible, to pair more than one
device to one channel of the NEA SMART 2.0 Base.
Each new paired device deletes the previous pairing
of another device, if it is done on the same channel.
7.4.2

Start pairing procedure on Base

To enter pairing mode, perform the following steps:
1
<
OK
>
> 3 sec
Press OK for > 3 seconds
5
RZ1
RZ2
RZ3
Confirm all zones you want to pair to one room unit by pressing OK short
Now you can pair the room unit. The NEA SMART
2.0 Base stays in the pairing mode for 3 minutes.
52
2
RZ1
RZ2
RZ3
The LED of the first zone, which is
ready for pairing, is blinking fast
6
<
OK
>
< 1 sec
3
<
OK
>
< 1 sec
Select the zone(s) for pairing: Con-
firm this zone by pressing OK short
7
RZ1
RZ2
RZ3
All selected zones are blinking con-
tinuously
4
<
OK
>
< 1 sec
or move to another zone
by using the keys "<"or">"