Rules For Overriding Individual Energy Levels By Global; Setting; Temporary Room Temperature Set Point Change; Permanent Room Temperature Set Point Change - Rehau NEA SMART 2.0 Service Manual

Hide thumbs Also See for NEA SMART 2.0:
Table of Contents

Advertisement

or the web pages for all rooms (global) or for each room individually.
When the global mode is selected using the web page, it is applied to all
rooms. When the App is used, it is possible to exclude a set of rooms.
On each room unit with a display it is also possible to choose one of
the energy levels for this room only.
Permanent selection
When a energy level is chosen, it is valid until it is changed.
Selection by timer program
The 5 weekly timing programs define the time spans for NORMAL and
REDUCED.
The used weekly timer program can be selected for each room
individually.
Automatic selection by geofencing
When this option is enabled, the system calculates the earliest
expected return time of the user. Room temperatures are kept on a
level, that the desired temperature level can be reached at return time.
Geofencing does not activate rooms which are set permanently
to one of the energy levels.
4.1.6

Rules for overriding individual energy levels by global

setting

When the user selects a global energy level on the web page, this
energy level is applied to all rooms. If for one single room an individual
energy level shall be activated, this can be done on the web page of
this room or on the room unit.
When the App is used, the application proposes a list of rooms, for
the global settings based on the rules listed below:
- General rules (using the App):
- Rooms which are running in timed mode are proposed to follow the
global command
- Rooms which are set to permanent energy level normal, reduced or
standby are not proposed to follow the global command
- Global command STANDBY proposes all rooms to follow
- Global command Party and holiday proposes all rooms which have
been selected the last time
Example 1:
The user selected for his hobby room the energy level REDUCED.
A room, which is only used from time to time for guests, is set to
"holiday/absence". All other rooms are running in timed mode, the
NORMAL level for these rooms is on working days from 6 h AM until
8 h AM and from 17 h PM to 23 h PM.
One working day, the user stays at home and he switches his
installation to global mode NORMAL.
20
Reaction of the App:
The App proposes all rooms except hobby room and the room for
guests to follow the global command NORMAL.
Example 2:
Some of the rooms in a house are used permanently or should by any
reasons not be set to lower energy level.
The user is off for several days and activates the holiday function. The
first time he must select the rooms where this function should be
applied. The next time he can just confirm the last selection of rooms.
4.1.7
Temporary room temperature set point change (timed
mode)
Room temperature set points of rooms, which are running in timed
mode, can be changed on the room unit, on web page or by the App.
This new set point is valid until the next switching point of the timing
program occurs.
4.1.8

Permanent room temperature set point change

When a room is in NORMAL or REDUCED, the room temperature set
point modification overrides the previous set point. By this method, it
is possible to (re)define the setpoints of room temperatures without
using the room configuration pages on the App or on the web pages.
Procedure for room unit:
- Select energy level (normal or reduced mode)
- Modify set point
- Go to desired mode (timed, normal, reduced)
- New set point is stored and will be used from now on for this energy
level.