Heating Circuits, Boost Function - Rehau NEA SMART 2.0 Service Manual

Hide thumbs Also See for NEA SMART 2.0:
Table of Contents

Advertisement

Key
Text in parameter menu Comment
MIXH12
Compensation factor for
room temperature
MIXH13
Boost mode allowed
Tab. 9-2 Parameter heating circuits
9.1.2

Heating circuits, boost function

To find in App:
Home  More  Settings  Installer  Control Parameters  Heating  Boost Mode
Key
Text in parameter menu Comment
BOO1
Nominal slope reduction
for return
BOO2
Measure time for boost
mode
BOO3
Hysteresis for boost mode The expected return temperature has to be undercut
BOO4
Compensation factor for
boost mode
BOO5
Boost mode cycle time
BOO6
Boost mode pause time
Abb. 9-1 Parameter heating circuits, boost mode
The function "Boost mode" is released separately for each heating circuit.
Influence of the deviation between set point and actu-
al value of room temperatures on flow temperature
The boost mode function is allowed. Should be indivi-
dual for each circuit.
The expected return temperature outside of the
heating-up phase is a result of a re-calculation of the
heating curve with a reduced slope. The percentual
reduction of slope is set here.
The expected return temperature has to be undercut
at least for this time span (see also BOO3)
at least for this value
The deviation to the expected return temperature
multiplied with compensation factor gives the increase
of the flow temperature (boost mode) for the time
defined in BO05
Time period for the boost mode
Pause time after a cycle time in boost mode
Min
Max
Base
value
0
5
0 : 1
1 : 1
2 : 1
false
true
0 : true
1 : true
2 : true
Min
Max
Base
value
10
70
40
0
99
10
0
4
1
0
5
2
10
120
30
10
120
30
Unit
Unit
%
min
K
min
min