Motor-side power components
9.3 dv/dt filter plus Voltage Peak Limiter
9.3.7

Technical data

Table 9- 29
Technical data of the dv/dt filter plus voltage peak limiter, 3 AC 380 ... 480 V, Part 1
Article number
Suitable for Motor Module
Type rating of the Motor
Module
I
thmax
Degree of protection
dv/dt reactor
Power loss
- At 50 Hz
- At 60 Hz
- At 150 Hz
Connections
- To the Motor Module
- Load
- PE
Max. permissible cable
length between dv/dt reac-
tor and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage peak limiter
Power loss
- At 50 Hz
- At 60 Hz
- At 150 Hz
Connections
- To the dv/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Two dv/dt reactors are required for these dv/dt filters. The technical data provided applies to one dv/dt reactor.
1)
Note
Cable lengths for versions with two dv/dt reactors
For versions with 2 dv/dt reactors, the cable lengths specified in the table do not change.
384
6SL3000-
2DE32-6AA0
6SL3320-
1TE32-1AA3
1TE32-6AA3
kW
110 / 132
A
260
IP00
kW
0.701
kW
0.729
kW
0.78
M10
M10
M6
m
mm
410
mm
370
mm
229
kg
66
kW
0.029
kW
0.027
kW
0.025
M8
M8
M8
mm
263
mm
265
mm
188
kg
6
2DE35-0AA0
2DE38-4AA0
1TE33-1AA3
1TE36-1AA3
1TE33-8AA3
1TE37-5AA3
1TE35-0AA3
1TE38-4AA3
160 / 200 / 250
315 / 400 / 450
490
IP00
0.874
0.904
0.963
M12
M12
M6
300 (shielded)
450 (unshielded)
460
370
275
122
0.042
0.039
0.036
Terminal 70 mm²
Terminal 70 mm²
Terminal 35 mm²
392
285
1312.5
210
16
Manual, 07/2019, 6SL3097-4AE00-0BP9
2DE41-4AA0
1TE41-0AA3
1TE41-2AA3
1TE41-4AA3
1TE41-4AS3
560 / 710 / 800 /
800
840
1405
IP00
IP00
1.106
1.111
1.115
1.154
1.226
1.23
M12
2 x M12
M12
2 x M12
M6
M6
460
445
385
385
312
312
149
158
0.077
0.134
0.072
0.125
0.066
0.114
M8
M10
M8
M10
M8
M8
309
309
1312.5
400
400
48
72
Air-cooled chassis power units