8.1.4.5

Installing the Braking Module in a Basic Line Module, frame size FB

Figure 8-12
Installing the Braking Module
The steps for the installation procedure are numbered in accordance with the diagram.
1. Unscrew the three screws of the blanking plate.
Remove the plate.
2. Insert the Braking Module where the cover used to be and secure it using the three
screws (from step 1).
3. Attach the adapter bar to the DCNA using a nut, so that the busbar cannot be twisted. For
this purpose, a small bolt is attached to the adapter bar, which must be located on the
lower side of the DCNA connection.
4. Secure the connecting cable to the DC link with two screws (Braking Module connection)
and two nuts (DC-link connection).
Air-cooled chassis power units
Manual, 07/2019, 6SL3097-4AE00-0BP9
Installing the Braking Module in a Basic Line Module, frame size FB
DC link components
8.1 Braking Module