Wavetronix SmartSensor V User Manual page 53

Hide thumbs Also See for SmartSensor V:
Table of Contents

Advertisement

Note. If you increase
the response
delay, you should
also increase
the additional
response wait time
that SmartSensor
Manager uses when
communicating
to the sensor.
 SmartSensor V User Guide
52
Setting
Expansion Port A/B
Response Delays (Milliseconds)
RS-232
RS-485
Exp. A/B
Advanced Comm Register
Simple Protocol
Flow Control
Description
Lets you set the baud
rate for expansion
port A and B.
Lets you set how long
the sensor will wait
before responding to
a received message,
shown in milliseconds.
Lets you set how long
the sensor will wait
before responding to
a received message,
shown in milliseconds.
Lets you set how long
the sensor will wait
before responding to
a received message,
shown in milliseconds.
Allows you to either
enable or disable
Simple SmartSensor
protocol.
Enables or disables
flow control
handshaking on the
sensor. Enable this
feature by selecting
RTS/CTS from the
drop-down menu.
Details
These ports are
currrently not
available for use.
Change this if
you're using a
communication
device that can't
quickly change
transmission direction
Change this if
you're using a
communication
device that can't
quickly change
transmission direction.
These ports are
currrently not
available for use.
By default, Simple
protocol is enabled.
Simple protocol must
be disabled if you
are using a multidrop
network or if you
plan on using RTMS
protocol.
Keep this set to
None unless you are
using a device that
requires hardware
handshaking.