Section 2 - Setup and Calibration
20. Press the up arrow on the arrow pad to highlight the "ACTUAL UP" option.
21. Press the left or right arrow on the arrow pad to adjust the "ACTUAL UP" tab percentage to match the "CURRENT
ACTUAL %."
22. Press the check button to save the calibration and go back to the "TAB CALIBRATION" screen.
23. If more than one tab exists on the vessel, perform steps 10–22 for the remaining tabs.
24. When all the tabs have been calibrated, end the calibration process by selecting the "X" button.
NOTE: After any change or customization to the VesselView configuration, a blue pop‑up message will appear as a
reminder to save the session. It is recommended that all session changes be saved before holding the " X " button while
keying all engines off. Refer to Section 1 ‑ Saving the Settings .
25. When calibrating the tabs is completed, press the right arrow on the arrow pad to continue to the "COMPLETE" screen.

Calibrating Trim

For power packages with trim, configure the trim settings on the "TRIM CALIBRATION" screen. VesselView does not display
the "TRIM CALIBRATION" screen for power packages without trim. To open the "TRIM CALIBRATION" screen, press the
menu button until the "Main" menu appears, then use the down arrow button to select the "Calibrate" option. Press the check
button to open the "Calibrate" menu. Press the down arrow button, then the check button to select "Trim."
NOTE: Trim calibration does not set the maximum engine trim and trailer limits. Refer to the engine installation manual for more
information on your specific engine.

Trim Calibration

1.
Open the "TRIM CALIBRATION" screen.
2.
The "TRIM ENGINE" box prompts you to trim all engines or drives "DOWN."
Page 24
45142
27204
90-8M0070299
MAY 2012
eng