Method 1: Default

1.
On the "TANK CALIBRATION" screen, press the check button to choose the "DEFAULT" calibration method. VesselView
displays a saving settings message.
2.
Repeat the tank calibration process for any additional tanks.

Method 2: Manual

1.
On the "TANK CALIBRATION" screen, press the "X" button to choose the "MANUAL" calibration method.
2.
Ensure the tank is empty. Press the check button to confirm.
3.
Following the direction on the screen, fill the tank to 25% of its capacity. Press the check button to confirm, or the back
button to go back one step.
4.
Following the direction on the screen, fill the tank to 50% of its capacity. Press the check button to confirm, or the back
button to go back one step.
5.
Following the direction on the screen, fill the tank to 75% of its capacity. Press the check button to confirm, or the back
button to go back one step.
6.
Following the direction on the screen, fill the tank to 100% of its capacity. Press the check button to confirm, or the back
button to go back one step.
90-8M0070299
MAY 2012
eng