Section 2 - Setup and Calibration
5.
Press the check button to confirm your choice. The "TYPE," "SIZE," and "LOCATION" boxes will appear.
6.
Use the left or right arrow button to scroll through the available tank types in the "TYPE" box. You may select any of the
following:
"NOT USED"
"OIL"
"WASTE"
"FUEL"
"WATER"
7.
Press the down arrow to proceed to the "SIZE" box.
8.
Use the right arrow button to scroll to the capacity of the tank. Holding the button down causes the scroll to speed up.
IMPORTANT: The default unit for measuring tank capacity is U.S. gallons. To choose a different unit of measurement,
refer to Section 4 ‑ Units.
9.
Press the down arrow to proceed to the "LOCATION" box. You may select any of the following:
"S1" (starboard 1), "S2" (starboard 2), "S3" (starboard 3), "SF" (starboard forward), or "SA" (starboard aft)
"P1" (port 1), "P2" (port 2), "P3" (port 3), "PF" (port forward), or "PA" (port aft)
"C1" (center 1), "C2" (center 2), "C3" (center 3), "CF" (center forward), or "CA" (center aft)
10. To change the values already entered, press the "X" button to return to the previous screen. Otherwise, press the check
button to confirm your selections. VesselView will then display two methods of calibration.

Tank Calibration

VesselView offers two tank calibration methods. For linear shaped fuel tanks, choose "METHOD 1: DEFAULT." Using method
1, VesselView assumes the tank is uniformly shaped and that each quarter of the tank holds a quarter of its total capacity. For
irregularly shaped fuel tanks, choose "METHOD 2: MANUAL." You will be required to fill the tank for the manual method.
Page 18
a -
Type of tank
b -
Size of tank
c -
Location of tank
a
b
c
27064
a -
Method 1 ‑ Default
b -
Method 2 ‑ Manual
a
b
27065
90-8M0070299