SiBE28-804
2.6

Removal of Thermistor

Procedure
Step
Remove the top panel
and the front panel (2)
and side panel
accordance with the
Procedure for Outside
Panels.
Pull out the outdoor air
1
temperature thermistor
to the front, and then
slide this thermistor to
the right to remove it.
Pinch the mounting
2
spring that fixes the
discharge pipe
thermistor to pull out
this thermistor.
Press the fixing section
3
of the suction pipe
thermistor to pull out
this thermistor.
4
Pull the fixing bracket of
the heat exchanger's
distribution pipe
thermistor to the front,
and then remove this
thermistor.
Press the fixing section
5
of the heat exchanger's
intermediate
temperature thermistor
to pull out this
thermistor.
Press the fixing section
6
of the liquid pipe
thermistor to pull out
this thermistor.
Removal Procedure
Warning
Be sure to commence the disassembling work after 10 minutes or
more elapsed from all power supplies have been turned off.
Procedure
Thermistor
Discharge pipe thermistor
(R2T)
Mounting
spring
thermistor
Suction pipe thermistor
(R3T)
Mounting
spring
Thermistor
Liquid pipe thermistor
(R6T)
1
*
The heat exchanger's distribution pipe thermistor, heat
exchanger's intermediate temperature thermistor, and
liquid pipe thermistor are jointed together with a single
connector. Consequently, these three thermistors
should be replaced at the same time.
RZQ100~140C7, RZQS125·140C7V1B
Points
Thermistor
Outdoor air thermistor (R1T)
Intermediate heat
exchanger thermistor (R5T)
Heat exchanger distribution
pipe thermistor (R4T)
Thermistor
283