Daikin RZQ71C7V1B Technical Data Manual
Hide thumbs Also See for RZQ71C7V1B:

Advertisement

1
Features
A
1
i
C 7 V
U n
y
S k
1 4 0
o r
1 0 A
7 1 -
t
t d o
l i
R Z Q
R - 4
S p
O u
Outdoor units for pair, twin, triple, double twin application
The Sky Air Inverter is developed for use in shops, restaurants and
small offices. This innovative Daikin unit provides a more
comfortable environment and offers great savings in energy
1
consumption to shop and office owners.
The use of inverter type outdoor units results in an air conditioning
1
system with a high energy efficiency and very low sound level
An inverter driven compressor allows the capacity to be adjusted
precisely to match variations in room and outside temperatures.
1
• Outdoor Units • R-410A • RZQ71-140C7V1B
• Split Sky Air • Outdoor Units
During start up, the room can be cooled down or heated very quickly.
Once the temperature in the room has reached its set point, the low
power operation starts to save energy.
Daikin outdoor units are neat and sturdy and can be mounted easily
on a roof or terrace or simply placed against an outside wall.
Outdoor units are fitted with either a swing or scroll compressor,
renowned for low noise and high energy efficiency
A special acryl precoated fin for anti-corrosion treatment on the heat
exchanger ensures greater resistance against severe weather
conditions

Advertisement

Table of Contents
loading

Summary of Contents for Daikin RZQ71C7V1B

  • Page 1 This innovative Daikin unit provides a more comfortable environment and offers great savings in energy • Daikin outdoor units are neat and sturdy and can be mounted easily consumption to shop and office owners. on a roof or terrace or simply placed against an outside wall.
  • Page 2: Specifications

    • Outdoor Units • R-410A • RZQ71-140C7V1B Specifications NOMINAL CAPACITY AND NOMINAL INPUT RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Indoor Units FCHQ71C7VEB FCHQ100C7VEB FCHQ125C7VEB FCHQ140C7VEB combination indoor units + outdoor units Cooling Standard 10.0 12.5 14.0 capacity Heating Standard 11.2 14.0 16.0...
  • Page 3 • Outdoor Units • R-410A • RZQ71-140C7V1B Specifications NOMINAL CAPACITY AND NOMINAL INPUT RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Nominal 3.01 3.01 combination Nominal 3.31 3.43 3.81 indoor units + Energy Label Cooling outdoor units Heating Annual energy consumption kWh 1,180 1725...
  • Page 4 • Outdoor Units • R-410A • RZQ71-140C7V1B Specifications TECHNICAL SPECIFICATIONS RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Compressor Quantity Motor Model 2YC63DXD JT100G-VD JT100G-VD JT100G-VD Type Hermetically sealed swing Hermetically sealed scroll compressor compressor Motor 1,700 2,200 2,200 2,200 Output Crankcas e Heater...
  • Page 5 • Outdoor Units • R-410A • RZQ71-140C7V1B Specifications TECHNICAL SPECIFICATIONS RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Safety Devices High pressure switch Fan motor thermal protector Fuse Standard Item Tie-wraps Accessories Quantity Item Installation manual Quantity Notes Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB, equivalent refrigerant piping : 5m, level difference : 0m.
  • Page 6: Electrical Data

    • Outdoor Units • R-410A • RZQ71-140C7V1B Electrical data RZQ(S)71-100C Unit combination Power supply Comp. Indoor uni t Outdoor uni t Hz-volts Vol t age range TOCA Max. 50Hz 264V Min. 50Hz 198V Max. 50Hz 264V Min. 50Hz 198V Max. 50Hz 264V Min.
  • Page 7 • Outdoor Units • R-410A • RZQ71-140C7V1B Electrical data RZQ100-125-140C Unit combination Power supply Comp. Indoor unit Outdoor unit Hz-volts Vol t age range MCA TOCA MFA MSC Max. 50Hz 264V Min. 50Hz 198V Max. 50Hz 264V Min. 50Hz 198V Max.
  • Page 8 • Outdoor Units • R-410A • RZQ71-140C7V1B Options RZQ100-125-140C Kit name Name of option RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Central drain plug KKPJ5F180 Refrigerant branch piping Twin KHRQ22M20TA Triple KHRQ127H Double twin KHRQ22M20TA (3x) Demand adapter kit KRP58M51 3TW26739-1E • Split Sky Air • Outdoor Units...
  • Page 9: Combination Table

    • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 1 Combination table Refrigerant R410A Thin cassette Hi casette 2x2 cassette Duct (medium ESP) Ceiling suspended 4way ceiling Wall mounted Model name Outdoor unit P = Pair 2 = Twin 35+35 50+50 3 = Triple...
  • Page 10 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 1 Combination table EDP room specifications Refrigerant R410A Thin cassette Hi casette 2x2 cassette Duct (medium ESP) Ceiling suspended 4way ceiling Wall mounted Model name Outdoor unit P = Pair 2 = Twin 50+50 3 = Triple...
  • Page 11: Cooling Capacity Tables

    • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 2 Cooling capacity tables RZQ71C7V1B Cooling Capacity range Rated point Cooling capacity Cooling Indoor Outdoor temp. (°CDB) (°C) (°C) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) 16.0 7.29 4.95...
  • Page 12 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 2 Cooling capacity tables RZQ100C Cooling Capacity range Rated point Cooling Capacity (kW) Cooling Indoor Outdoor temperature (°C DB) °C °C (kW) (kW) ( - ) (kW) (kW) ( - ) (kW) (kW) ( - )
  • Page 13 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 2 Cooling capacity tables RZQ125C Cooling Capacity range Cooling Capacity (kW) Rated point Cooling Indoor Outdoor temperature (°C DB) °C °C (kW) (kW) ( - ) (kW) (kW) ( - ) (kW) (kW) ( - )
  • Page 14 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 2 Cooling capacity tables RZQ140C Cooling Capacity range Cooling Capacity (kW) Rated point Cooling Indoor Outdoor temperature (°C DB) °C °C (kW) (kW) ( - ) (kW) (kW) ( - ) (kW) (kW) ( - )
  • Page 15 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 2 Cooling capacity tables RZQ140C (Pair) Cooling Cooling capacity (Rated point) Capacity range Cooling capacity 400V [50Hz] I n door Outdoor temp. (°CDB) (°C) (°C) (kW) (kW) (kW) (kW) (kW) (kW) (kW)
  • Page 16 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 2 Cooling capacity tables RZQ-B/C Capacity in function of field piping length for non-inverter Capacity (%) Field piping length (m) 3TW26062-1 Cooling Heating • Split Sky Air • Outdoor Units...
  • Page 17: Heating Capacity Tables

    • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 3 Heating capacity tables RZQ71C7V1B Heating Rated point Capacity range Heating capacity Heating Indoor Outdoor temp. (°CWB) −15 −10 −5 (°C) (kW) (KW) (kW) (kW) (kW) (kW) 16.O 5.14 0.89...
  • Page 18 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 3 Heating capacity tables RZQ100C Heating Capacity range Rated point Heating Capacity (kW) Heating Indoor Outdoor temperature (°C DB) °C (kW) ( - ) (kW) ( - ) (kW) ( - ) (kW) ( - )
  • Page 19 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 3 Heating capacity tables RZQ125C Heating Capacity range Rated point Heating Capacity (kW) Heating Indoor Outdoor temperature (°C DB) °C (kW) ( - ) (kW) ( - ) (kW) ( - ) (kW) ( - )
  • Page 20 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 3 Heating capacity tables RZQ140C Heating Capacity range Heating Capacity (kW) Rated point Heating Indoor Outdoor temperature (°C DB) °C (kW) ( - ) (kW) ( - ) (kW) ( - ) (kW) ( - )
  • Page 21 • Outdoor Units • R-410A • RZQ71-140C7V1B Capacity tables 5 - 3 Heating capacity tables RZQ140C (Pair) Heating Heating capacity (Rated point) Capacity range Heating capacity 400V [50Hz] I n door Outdoor temp. (°CWB) −15 −10 −5 (°C) (kW) (kW) (kW) (kW) (kW)
  • Page 22: Dimensional Drawing & Centre Of Gravity

    • Outdoor Units • R-410A • RZQ71-140C7V1B Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing unit (mm) RZQ-C Hole for anchor bolt Gas pipe connection J15.9 flare 4-M12 Liquid pipe connection - J9.5 flare Service port (in the unit) Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake (knock out hole J34)
  • Page 23: Centre Of Gravity

    • Outdoor Units • R-410A • RZQ71-140C7V1B Dimensional drawing & centre of gravity 6 - 2 Centre of gravity RZQ71C7V1B 4TW30469-3 RZQ100-125-140C 4TW29169-4 • Split Sky Air • Outdoor Units...
  • Page 24: Piping Diagram

    • Outdoor Units • R-410A • RZQ71-140C7V1B Piping diagram RZQ71-140C (Pair) Electronic expansion valve Heat exchanger Filter Filter 4-way valve Heat exchanger High pressure Low pressure switch sensor Field piping J9.5 C1220T-0 Service port Compressor 5/16″ Filter Field piping J15.9 C1220T-0 Accumulator Indoor unit Outdoor unit...
  • Page 25 • Outdoor Units • R-410A • RZQ71-140C7V1B Piping diagram RZQ71-140C (Triple) Indoor unit Heat exchanger Electronic expansion valve Stop valve Heat exchanger (with service port 5/16’ flare) Filter Filter Field piping Filter Field piping Indoor unit Heat exchanger 4-way valve High pressure Field piping J9.5 Low pressure...
  • Page 26: Wiring Diagram

    • Outdoor Units • R-410A • RZQ71-140C7V1B Wiring diagram 8 - 1 Wiring diagram RZQ71C7V1B : Printed circuit board Power supply Wiring diagram : Printed circuit board 220-240V∼50Hz Indoor unit BS1∼BS4 : Push button switch C1∼3 : Capacitor : Dip switch : Fuse (T 6.3A/250V)
  • Page 27: Sound Pressure Spectrum

    • Outdoor Units • R-410A • RZQ71-140C7V1B Sound data 9 - 1 Sound pressure spectrum RZQ71C7V1B - Cooling RZQ71C7V1B - Heating 3TW30487-2 Octave band center frequency (Hz) 3TW30487-1 Octave band center frequency (Hz) NOTES NOTES 1 Data is valid at free field condition...
  • Page 28 • Outdoor Units • R-410A • RZQ71-140C7V1B Sound data 9 - 1 Sound pressure spectrum RZQ125CV1 - Cooling RZQ125CV1 - Heating 3TW29197-1 3TW29197-2 Octave band center frequency (Hz) Octave band center frequency (Hz) NOTES NOTES Data is valid at free field condition Data is valid at free field condition Data is valid at nominal operation condition Data is valid at nominal operation condition...
  • Page 29: Sound Power Spectrum

    • Outdoor Units • R-410A • RZQ71-140C7V1B Sound data 9 - 2 Sound power spectrum RZQ71C7V1B RZQ100CV1 3TW30487-3 Octave band center frequency (Hz) 3TW29187-3 Octave band center frequency (Hz) NOTES 1 dB(A) = A-weighted sound power level (A-scale according to IEC) 2 Reference acoustic intensity 0dB=10E-6μW/m_...
  • Page 30: Installation Method

    • Outdoor Units • R-410A • RZQ71-140C7V1B Installation 10 - 1 Installation method RZQ71-140C A. Non stacked installation Legend Suction side obstacle Discharge side obstacle Left side obstacle Right side obstacle Top side obstacle Obstacle is present In these cases, close the bottom of the installation frame to prevent discharged air from being bypassed.
  • Page 31: Operation Range

    • Outdoor Units • R-410A • RZQ71-140C7V1B Operation range RZQ71-140CV1B Cooling Heating Indoor temp. (°CWB) Indoor temp. (°CDB) Notes: - Depending on operation and installation conditions, the indoor unit can change over to freeze-up operation (indoor de-icing). - To reduce the freeze-up operation (indoor de-icing) frequency, it is recommended to install the outdoor unit in a location not exposed to wind.

This manual is also suitable for:

Rzq100c7v1bRzq125c7v1bRzq140c7v1b

Table of Contents