Removal of PC Board Assy (2)

Procedure
Step
2. Remove the mounting
plate for the electric
component
Remove the mounting
1
plate for the terminal
block, after removing
the one screw.
Remove the two
2
connectors on the
reactor.
Cut three clamps that
3
fix the wiring.
4
Remove the mounting
plate for the electric
component after
removing the two
screws
272
Warning
Be sure to commence the disassembling work after 10 minutes or
more elapsed from all power supplies have been turned off.
Procedure
Fixing screws
Mounting plate for
the terminal block
After removing the mounted electric component
X106A
X6A
X5A
X21A
X13A
X11A
X41A
X12A
LB
X17A
X25A X77A X803A
Mounting plate for
the electric component
Connectors
Reactor
Fixing screw
Clamps
IPM501
X11A
U
V
W
DB501
Q501
LC
D532
D531
DB502
NA
LA
E
SiBE28-804
Points
(cf)