Removal Of Compressor - Daikin SkyAir Service Manual

R-410a, 50hz
Hide thumbs Also See for SkyAir:
Table of Contents

Advertisement

SiBE28-804

1.10 Removal of Compressor

Procedure
Step
Collect the refrigerant.
Remove the outside
panels, their parts, and
the switch box, following
the procedure indicated at
"Removing Outside
Panels and Related Parts"
and other instructions.
Remove the fixing plate
1
for the stop valve after
removing the five
screws.
Remove the sound
2
insulation (1).
Remove the terminal
3
cover, after pushing the
projective parts from
the both sides.
Remove the lead wire
4
from the terminal (2).
Pull out the sound
5
insulation by unwinding
the strings (two
locations).
Remove the nuts that
6
fix the compressor. (All
the equipments are
fixed with three nuts).
7
Cut off the brazing (two
locations).
Pull out the compressor
8
by lifting upward.
Removal Procedure
Warning
Be sure to commence the disassembling work after 10 minutes or
more elapsed from all power supplies have been turned off.
Procedure
Fixing plate for the stop valve
Fixing nuts
Sound insulation (1)
Terminal cover
Brazings
RZQ71C7, RZQS71·100C7V1B
Be sure to confirm that the
refrigerant is completely
collected before starting the
work.
The color of each terminal
One of the fixing nuts of the
compressor is located at the
outer side of the partition
plate.
Sound insulation (2)
String
Points
Rubber bush
Glass terminal
U
V
W
U: Red V: White W: Blue
277