Download Print this page

Removal Of Compressor Assy - Daikin RE09HV2S Removal Procedure

Outdoor unit

Advertisement

Si01-882

5. Removal of Compressor ASSY

Procedure
Step
Remove the nut and
1
remove the terminal
cover.
Disconnect the
2
compressor lead wires.
3
Remove the 3 nuts of
the compressor.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Terminal
cover
(R15244)
(R15245)
(R15442)
Removal of Compressor ASSY
Points
S(W)
C(U)
R(V)
(R15393)
S(W) : yellow
C(U) : blue
R(V) : red
13

Advertisement

loading

This manual is also suitable for:

Re12hv2s