6.9.2

Filtering DI.0, DI.1, DI.2 and CI

Specify the following values for filtering the digital inputs and the counter input:
Selection codes
Filter DI.0 [filterDI0]
Filter DI.1 [filterDI1]
Filter DI.2 [filterDI2]
Filter CI [filterCI]
0 (default)
1 ... 2500 [0.1 ms]
6.9.3

Assignment DQ.0, DQ.1, DQ.2

Selection code
[functionDQ0]
[functionDQ1]
[functionDQ2]
0 ... 79
80
81
100 ... 179
255 (default)
1000 ... 1063
1100 ... 1163
2000 ... 2063
2100 ... 2163
3000 ... 3063
3100 ... 3163
See also
Commands (Page 111)
6.9.4

Reaction to CPU stop / failure [behaviourOnCPUStopOrFailure]

Selection code
0 (default)
1
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA
Function
Corresponding bit of the scale status (see DR30)
Controlled via S7 I/O
Controlled via data record 18
Corresponding inverted bit of the scale status (see DR30)
Output deactivated
Corresponding operating error (see DR32)
Corresponding inverted operating error (see DR32)
Corresponding technology message (see DR32)
Corresponding inverted technology message (see DR32)
Corresponding data/operating error (see DR32)
Corresponding inverted data/operating error (see DR32)
Function
Active dosing is stopped
Active dosing is continued
Parameter assignment/addressing
6.9 DR07 Interface parameters
Function
No filtering
Filtering from 0.1 to 250 ms
73