Data And Command Errors - Siemens SIMATIC ET 200SP Operating Instructions Manual

Technology module
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Technology messages
2122 Inhibition time "extra coarse" error 2122
2123 Extra coarse shut-off point already
exceeded
2096 Restore point set
2094 Backup/snapshot set
2095 Backup loaded
2097 Restore point loaded
2098 Standard parameters loaded
2099 Factory settings loaded
9.4.3

Data and command errors

Table 9-2
Data and command errors
Data and command errors
5000 Data/command errors
6050 Unknown command
6051 Command not possi‐
ble now
6052 Service command er‐
ror
6053 Calibration command
error
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA
Error code
2123
2096
2094
2095
2097
2098
2099
Error code
Add info
[errorCode]
[errorAd‐
dInfo]
5000
-
6050
-
6051
-
9500
9501
9502
9507
9514
9541
9680
9681
6052
9510
9511
9507
9512
9522
6053
9510
Description and remedy
Inhibition time extra course. After expiration of the inhibition time
extra coarse, the extra coarse shut-off point was already exceeded
The extra coarse shut-off point is already exceeded before switch‐
ing on the extra coarse signal
A recovery point was successfully set.
Backup/snapshot was successfully set.
Backup (or default values, if no backup) has been successfully loa‐
ded.
A recovery point was successfully loaded.
The standard parameters were successfully loaded.
The factory settings were successfully loaded.
Description
Group error, at least one data/operating error present
Issued command code is unknown. Check the command code.
The desired command could not be executed because, for exam‐
ple, another process is already active at this time. Additional infor‐
mation contains details.
Fault present
No stability
Waiting for stability
Dosing active
CPU is missing or not ready
Emptying active
SecureDisplay is missing or not visible
Display command does not match the current display content of
SecureDisplay
Commands from the Service commands group could not be exe‐
cuted. Additional information contains details.
Service mode not active
Write protection enabled
Dosing active
Missing enable
Calibration not yet complete
Command from the Calibration commands group could not be exe‐
cuted. Additional information contains details.
Service mode not active
Interrupts/diagnostic messages
9.4 Operating errors
133

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm siwarex wp351 hf

Table of Contents