Parameter assignment/addressing

6.21 DR28 Configuration of additional string for protocols

6.20.14

Dosing signals

Dosing signals during extra coarse phase [feedOptionsXCoarse]
Defines which signals are switched in the "Extra coarse" dosing phase in three-stage dosing
(with extra coarse, coarse and fine phase).
Selection code
0 (default)
1
3
7
Dosing signals during coarse phase [feedOptionsCoarse]
Defines which signals are switched in the "coarse" dosing phase.
Selection code
1 (default)
3
6.20.15

Delete tare in weighing step 0 [deleteTareStep0]

Selection code
0 (default)
1
6.21
DR28 Configuration of additional string for protocols
6.21.1

Log with additional string [addAdditionalText]

The freely definable additional string [additionalText] with 42 characters is transmitted from the
CPU to the electronic weighing system. When you save the additional string in the protocol,
extra information such as batch numbers or similar is saved in the scale protocols.
Selection code
[addAdditionalText]
0 (default)
1
102
Meaning
Extra coarse phase is omitted
Only "Extra coarse signal"
"Extra coarse signal" + "Coarse signal"
"Extra coarse signal" + "Coarse signal" + "Fine signal"
Meaning
Only with coarse signal
With coarse and fine signal
Meaning
Do not delete tare
Delete tare memory automatically on transition to weighing step 0
Meaning
Do not save additional string in protocol
Save additional string in protocol