Form Of Speed Output Signal - HBM T10FS Operating Manual

Torque flange
Hide thumbs Also See for T10FS:
Table of Contents

Advertisement

54

7.7 Form of speed output signal

In the factory setting, two 90_ phase‐offset speed signals (5 V symmetrical,
complementary RS-422 signals) are available at the speed output (connector
2). You can double the pulse count set in each case by moving switch S6 to
the "On" position. Pin 3 then outputs the direction of rotation as a static
direction of rotation signal (pin 3 = +5 V, pin 7 = 0 V compared to pin 8), if the
shaft turns in the direction of the arrow). At a speed of 0 min
rotation signal has the last measured value.
Fig. 7.10:
Direction of rotation arrow on the head of the sensor
Fig. 7.11:
Switch for doubling the pulses
HBM
Switch S6
T10FS
-1
, the direction of
Direction of rotation
arrow
Doubling the pulses
On
Off
S6