Spectrum scope screen
The spectrum scope enables you to display the
activity on the selected band, as well as the
relative strengths of various signals in that band.
The transceiver has two spectrum scope modes,
the Center mode and the Fixed mode. You can
also turn the Waterfall display ON or OFF.
In addition, you can select the Mini scope to
display the scope in a smaller size on the screen.
• Center mode screen
Center/Fixed mode icon
Span (Display range)
Operating frequency (stays in the Center)
Waterfall zone
• Fixed mode screen
Center/Fixed mode icon
Edge (Lower frequency)
Operating frequency (moves)
Waterfall zone
Marker
D
The Marker displays the operating frequency in
the SPECTRUM SCOPE screen.
R: The RX marker
• Marks the receive frequency.
T: The TX marker
• Marks the transmit frequency.
• About RX Marker
In the Fixed mode, the RX Marker displays the
operating frequency within a specified frequency
range. So, the transceiver always displays the RX
marker in the Scope screen.
In the Center mode, the operating frequency stays in
the center of the screen. Thus, the transceiver does
not display the RX Marker.
LWhen the Hold function is ON, the RX Marker is
displayed to indicate the operating frequency's
location.
Span (Display range)
Grid (frequency/level)
FFT scope zone
(FFT: Fast Fourier Transform)
Edge (Upper frequency)
Grid (frequency/level)
FFT scope zone
SCOPE OPERATION
DUsing the Spectrum Scope
Display the SPECTRUM SCOPE screen.
» SCOPE
Key
< 1 >
Selects the Function menus.
< 2 >
Touch
SPAN
Touch for
1 second
In the Fixed mode, selects the Edge
frequencies.
L You can set the upper and lower Edge
EDGE
frequencies in "Fixed Edges" on the
SCOPE SET screen by touching [EXPD/
SET] for 1 second.
Touch
HOLD
Touch for
1 second
CENT/FIX Selects the Center or Fixed mode.
Touch
EXPD/SET
Touch for
1 second
Opens the "REF Level" window.
L Rotate
REF
level.
L Touch again to close the window.
Selects the sweep speed.
SPEED
• "" (FAST), "" (MID), or "" (SLOW).
MARKER Selects the Marker.
5-1
MENU 1: Center mode
MENU 1: Fix mode
MENU 2: Center/Fix mode
Action
In the Center mode, selects the
scope span.
• ± 2.5, 5.0, 10, 25, 50, 100, 250,
or 500 kHz
Resets to the ±2.5 kHz span.
Turns the Hold function ON or
OFF.
•
and the Marker are
HOLD
displayed. Freezes the current
spectrum.
Clears the Peak Hold level.
Selects the Expanded or Normal
screen.
Displays the SCOPE SET screen.
to adjust the Reference
5
5
Need help?
Do you have a question about the IC-705 and is the answer not in the manual?