Appendix A

Converting the Hydraulic Control Valve

®
AutoBoom
Valves with Square Coils
Perform the following procedure to convert an AutoBoom hydraulic control valve with the square coils to
operate in PowerGlide Plus mode:
Locate the needle valves installed in the ports labeled 'RT' and 'LF' on the AutoBoom control valve.
1.
Needle Valve Location
FIGURE 1.
Loosen the jam nuts on the needle valves.
2.
Use an Allen wrench to turn the set screws the set screws counter-clockwise until the screw will not turn any
3.
further.
Re-tighten the jam nuts.
4.
Set the Raven OS device to operate the AutoBoom feature in PowerGlide Plus mode. Review the
5.
AutoBoom® Features Tab section on page 14 to properly configure the Raven OS.
Note:
When converting the AutoBoom system back to UltraGlide mode, the set screws must be turned
clockwise until the screw will not turn any further and the Raven OS must be reset to operate in
UltraGlide mode.