Reset Calibration

Although it is not normally necessary, there may be circumstances under which it may be desired to reset the
AutoBoom system calibration. The AutoBoom system must be recalibrated after the system is reset. To reset
the AutoBoom system calibration:
Touch the Edit icon in the Machine Configuration panel to expand the panel.
1.
Locate and select the AutoBoom button. The AutoBoom Features tab will be displayed.
2.
Touch the Calibrate tab and select the Reset Defaults icon in the lower, left corner of the tab.
3.
When prompted to accept the reset, touch 'Yes' to proceed.
4.
Note:
Resetting the AutoBoom system calibration will delete all system settings and adjustments that
have been performed. Before resetting the AutoBoom calibration, refer to the Reset Defaults
section on page 21.
Refer to the PowerGlide Plus Calibration section on page 9 or the UltraGlide Calibration section on page 11
5.
to recalibrate AutoBoom before engaging the system during a field operation.

PowerGlide Plus Calibration

Important:
Read and perform the process outlined in the Pre-Calibration Hydraulic Diagnostics section on page 8
before starting the calibration process.

Boom Calibration

Edit
Touch the Edit icon in the Machine Configuration panel to expand the panel.
1.
Locate and select the AutoBoom button. The AutoBoom Features tab will be displayed.
2.
Note:
If the AutoBoom button is not displayed or displays as unavailable, refer to Chapter 5,
Troubleshooting, to diagnose and correct issues with the AutoBoom control node.
On the Features tab, select the options desired for operation of the AutoBoom system. Refer to the
3.
AutoBoom® Features Tab section on page 14 for additional information on the available features.
Touch the Sensor Offsets tab to access sensor height offset settings.
4.
If ultrasonic sensors are installed, use the up and down arrows to set the vertical offset of the sensor body
5.
from the spray nozzle for each sensor location. Refer to the Sensor Offsets Tab section on page 15 for
details on setting or adjusting the sensor offsets.
Select the Calibrate tab to access the AutoBoom calibration.
6.
Manual No. 016-0130-076 Rev. C
Edit
AutoBoom
AutoBoom
Calibrate
Features
Sensor
Tuning
Offsets
Calibration
Calibrate
9