Chapter 3

Pre-Calibration Hydraulic Diagnostics

While every effort has been made to properly label and document connections for the hydraulic and electrical
components of the AutoBoom
and model of the machine. This makes it especially important to trace the hoses from the connection points
and verify electrical connections are correct to ensure proper AutoBoom system operation.
To test that the AutoBoom system will be able to operate as intended, perform the following procedure:
Touch the Edit icon in the equipment profile panel to expand the Machine Configuration panel and view
1.
available system devices.
Locate and select the AutoBoom button.
2.
Note:
If the AutoBoom button is not displayed or displays as unavailable, refer to Chapter 5,
Troubleshooting, to diagnose and correct issues with the AutoBoom control node.
Select the Diagnostics tab.
3.
Use the machine joystick or panel controls to operate the following boom functions and verify that the
4.
Raven OS displays and updates the status changes properly:
Raise and lower functions for the left and right booms.
Raise and lower functions for the center rack.
Fold and unfold functions.
Sensor heights (if installed).
Hydraulic pressures.
Note:
Refer to the Diagnostics Tab section on page 23 for details on reviewing AutoBoom status updates
while checking the above functions.
8
®
system, some connections may not be identified due to changes in the make
Edit
AutoBoom
Booms may raise or lower quickly or suddenly
during the testing process. To avoid serious
injury or death, keep the area around the
implement clear of bystanders during the test
process.
Diagnostics
DANGER
AutoBoom® Calibration & Operation Manual