After the plumbing has been rinsed of debris, the Hawkeye nozzle control valves may be mounted to the existing
nozzle bodies.

BEST PRACTICES AND RECOMMENDATIONS

• Do not connect battery leads until all cables are installed and connected.
• If a dual channel turret nozzle body is installed on the implement, always mount the Hawkeye nozzle control
valve to the straight nozzle port to avoid excessive pressure drop across the nozzle.
• If there are obstacles that interfere with the Hawkeye valve installation it may be necessary to purchase a
different brand of nozzle body with a threaded port on the opposite side.
GENERAL VALVE INSTALLATION
FIGURE 1. Valve Face O-Ring and Nozzle Control Valve
Valve Body Face
O-Ring
1. Place a supplied o-ring on the inside of the fly nut flush with the valve body face.
NOTE:
If using TeeJet QJS (straight) nozzle bodies, use the green coated (size 115) o-ring. For TeeJet QJ
(turret) nozzle bodies, use the brown/gray (size 116) o-rings.
For AGCO Hypro nozzle bodies, use the green coated (size 115) o-ring.
P/N 016-0171-640 Rev. A