Injection Tab; Injection Calibration Tab; Pressure Settings Tab - Raven Sidekick Pro Installation And Operation Manual

Can injection for case ih 3/4xxx
Table of Contents

Advertisement

INJECTION TAB

To access the Injection tab:
1. Touch the Edit icon in the Machine Panel to view the Machine Devices.
2. Locate and select the Product Control button.
3. Touch the Injection tab.
4. Touch the product indicators along the left of the prompt to select the control channel to which the pump is
assigned. Depending upon the injection system connected, the following options may be available:
Set Pump Type to High Volume. The type of pump used for chemical injection must be selected during the
initial product calibration for each injection pump connected to the control system.
Initial Meter Cal. Set the desired value of the meter cal to 110 and pulses/10 oz. for US units, or 372 and pulses /10
dL for SI units. The meter cal value for the Sidekick injection pump may be found on the label affixed to the
pump motor or the flow sensor connector. Enter this value as the initial meter cal.
FIGURE 1. Sidekick Pro Pump Label with Meter Cal
NOTE:
The meter cal may be adjusted to refine calibration of the chemical injection pump. Refer to the
injection system for assistance with checking or refining the meter cal.
Set Motor Cal. Set the motor cal (valve cal) value to 123.
Set Motor Cal 2. Set the motor cal 2 (valve cal 2) to 5054.

INJECTION CALIBRATION TAB

Refer to Sidekick Pro™ Injection Pump Priming and Calibration section on page 66 for injection pump calibration.

PRESSURE SETTINGS TAB

PRESSURE SETTINGS
NOTE:
The Pressure Settings tab features are only available when interfacing with a Sidekick Pro injection
system.
Viper 4 (ROS) Initial Set-Up: Injection Settings, Setup, and Definitions
Edit
Product
Control
VIPER 4 (ROS) INITIAL SET-UP
Injection
63