3.12.3

Installing a System Fan

Install a 60x60x56mm fan by completing the following steps.
1. Ensure the airflow arrow on the fan label on the top of the fan is pointed towards the rear of the system.
2. Position the fan over the socket to receive the fan and lower the fan into the socket.
3. Push the fan assembly downward until the locking tab clicks into place.
Install an 80x80x80mm fan by completing the following steps.
1. Ensure the airflow arrow on the fan label on the top of the fan is pointed towards the rear of the system.
Position the fan over the socket to receive the fan and lower the fan into the socket.
2. Lower the fan into the socket, and push it downward until it clicks into place (see Letter A).
3. Connect the power cable by pushing the connector into the socket until the locking tab clicks (see
Letter B).
4. Carefully route the cable underneath the flange and make sure the cable is routed through the notch
in the circuit board (see Letter C).
54
Intel® Server System R2600SR Setup and Service Guide

Figure 43. Installing the 60x60x56mm fan

Figure 44. Installing a 80x80x80mm fan