Structure Emergency Message - Festo CPV GE-CO2-8 Series Electronic Manual

Cpv valve terminal with direct connection
Hide thumbs Also See for CPV GE-CO2-8 Series:
Table of Contents

Advertisement

3. Diagnosis

3.3.1 Structure Emergency Message

Byte 0
Byte 1
Error Code
Fig. 3/5: Structure of Emergency Object, further information in Fig. 3/6 ... Fig. 3/11
Festo P.BE-CP-CO2-EN en 0107NH
The CPV Direct send an Emergency Message if there is an
error. Parallel to this, the Pre-defined error field (index 1003)
will be written with the relevant error message by:
Byte 0 and byte 1 of the Manufacturer status register
(index 1002) (corresponds to bytes 3 and 4 of the
Emergency Object)
Error Code as per DS301
The former fields will be shifted in the Pre-defined error field
by one position each (see chapter 2.4, index 1003, subindices
1...A).
Bytes 3 to 7 of the Emergency Message correspond to the
Manufacturer specific error field and contain device-typical
error messages.
Byte 2
Byte 3
Byte 4
Error
Error
Error
Register
summary
detail
Manufacturer specific error field
Error memory
The last 10 errors are saved in compressed form in the
Pre-defined error field (index 1003):
Error summary, Error detail, Error Code
Further information can be found in the object directory in
chapter 2.4.1.
Byte 5
Byte 6
Byte 7
Error
Condition
Reserved
Status
source
3-9