Motor Temperature Monitoring With Kty - Lenze 9300 Series System Manual

Vector
Hide thumbs Also See for 9300 Series:
Table of Contents

Advertisement

6.6
Adjusting the motor
6.6.4

Motor temperature monitoring with KTY

6.6.4
Motor temperature monitoring with KTY
Description
Codes for parameter setting
Code
Possible settings
No.
Name
Lenze Selection
C0121 OH7 limit
150
C0583 MONIT OH3
3
C0584 MONIT OH7
3
6.6−10
Via the incremental encoder connection X8 a KTY resistor can be connected
to pin X8/5 and X8/8. The motor temperature is detected and integrated in
the drive monitoring.
The KTY resistor is monitored with regard to interruption and short circuit.
We recommend to always activate the KTY input when using motors which
are equipped with KTY resistors. This serves to prevent the motor from being
destroyed by overheating.
(
Stop!
The controller can only evaluate one KTY resistor! Do not
ƒ
connect several KTY resistors in series or parallel:
– The motor temperature would be measured incorrectly.
– The motors could be destroyed by overheating.
If several motors are operated on one controller, use thermal
ƒ
contacts (NC contacts) connected in series for motor
temperature monitoring.
To achieve full motor protection, an additional temperature
ƒ
monitoring with separate evaluation must be installed.
45
{1 °C}
0
TRIP
2
Warning
3
Off
2
Warning
3
Off
l
IMPORTANT
150 Setting of the operating
temperature for monitoring OH7
l
Only for KTY at X8
l
Monitoring OH7 is configured
in C0584
Configuration of motor
temperature monitoring with
fixed operating temperature
l
Only for KTY at X8
l
The operating temperature is
fixed at 150 °C
Configuration of monitoring
motor temperature with variable
operating temperature
l
Only for KTY at X8
l
When reaching the
temperature set in C0121 the
warning OH7 is activated
EDSVF9383V EN 7.1−04/2012
^
6.6−10
See System
Manual
(extension)
^
6.6−10
See System
Manual
(extension)
^
6.6−10
See System
Manual
(extension)