Motor Temperature Monitoring With Ptc Or Thermal Contact 6.6−8 - Lenze 9300 Series System Manual

Vector
Hide thumbs Also See for 9300 Series:
Table of Contents

Advertisement

6.6
Adjusting the motor
6.6.3
Motor temperature monitoring with PTC or thermal contact
Information on the motor
nameplate
Field
C0086
C86
Type
1089
MDEBAXM−080−12
252
1090
MDEBAXM−080−32
213
1091
MDEBAXM−080−32
253
1092
MDEBAXM−090−12
214
1093
MDEBAXM−090−12
254
1094
MDEBAXM−090−32
215
1095
MDEBAXM−090−32
255
1096
MDEBAXM−100−12
216
1097
MDEBAXM−100−12
256
1098
MDEBAXM−100−32
217
1099
MDEBAXM−100−32
257
1100
MDEBAXM−112−22
218
1101
MDEBAXM−112−22
258
1102
MDEBAXM−112−32
219
1114
MDFMAxx−200−32
224
1115
MDFMAxx−200−32
264
6.6.3
Motor temperature monitoring with PTC or thermal contact
Description
6.6−8
C0022
C0081
C0084
C0085
Imax
P
R
Ls
r
s
[A]
[kW]
[W]
[mH]
4.16
0.95
20.69
89.00
3.00
0.75
11.69
65.20
5.20
1.30
11.69
65.20
4.05
1.10
6.40
37.00
7.05
2.00
6.40
37.00
5.40
1.50
4.80
26.00
9.30
2.70
4.80
26.00
7.20
2.20
2.90
20.00
12.45
3.90
2.90
20.00
9.90
3.00
2.10
17.00
17.10
5.35
2.10
17.00
12.45
4.00
1.50
11.00
21.45
7.10
1.50
11.00
17.85
5.50
2.71
21.40
83.25
30.00
˘
˘
145.50
52.00
˘
˘
PTC resistors according to DIN 44081 and DIN 44082 can be connected via
the terminal inputs T1 and T2. The motor temperature is measured and
integrated into the drive monitoring.
A thermal contact (NC contact) can also be connected to T1 and T2. Lenze
three−phase AC motors provide thermal contacts as default.
When using motors equipped with PTC resistors or thermostats, we
recommend to always activate the PTC input. This prevents the motor from
being destroyed by overheating.
(
Stop!
The motor temperature monitoring may only be connected to
ƒ
T1, T2 if the cable is terminated with a PTC or thermal contact
(NC contact) on the motor side.
– An "open" cable acts like an antenna and can cause faults on
the drive controller.
– Input signals at T1, T2 are processed with a delay of 2 s.
The drive controller can only evaluate one PTC resistor! Do not
ƒ
connect several PTC resistors in series or in parallel:
– The motor temperature would be measured incorrectly.
– The motors could be destroyed by overheating.
If you operate several motors on a drive controller, use
ƒ
thermal contacts (NC contacts) for motor temperature
monitoring and connect these in series.
To achieve full motor protection, an additional temperature
ƒ
monitoring with separate evaluation must be installed.
l
Motor data
C0087
C0088
C0089
C0090
C0091
n
IN
f
U
N
r
r
[rpm]
[A]
[Hz]
[V]
2510
2.77
87
400
1400
2.00
50
400
2510
3.46
87
400
1420
2.70
50
400
2535
4.70
87
400
1415
3.60
50
400
2530
6.20
87
400
1425
4.80
50
400
2535
8.30
87
400
1415
6.60
50
400
2530
11.40
87
400
1435
8.30
50
400
2545
14.30
87
400
1425
11.90
50
400
1465
55.50
50
400
2575
97.00
87
400
C0070
C0071
C0075
C0076
cos j
V
T
V
pn
nn
pi
0.68
6
300
1.6
0.72
6
300
3.5
0.72
6
300
1.9
0.77
6
300
2.5
0.77
6
300
2
0.77
6
300
2
0.77
6
300
1
0.80
6
300
1
0.80
6
300
0.8
0.81
6
300
2.5
0.81
6
300
1.4
0.82
6
300
2
0.82
6
300
1
0.84
6
300
1.5
0.85
6
300
1
0.85
6
300
1
EDSVF9383V EN 7.1−04/2012
T
ni
2
2
3
2
2
2
2
1.5
1.5
1.5
1.8
2
2
10
2
2

Hide quick links:

Advertisement

Table of Contents
loading