Wiring Of Motor Temperature Monitoring - Lenze 9300 vector Series Mounting Instructions

Global drive
Hide thumbs Also See for 9300 vector Series:
Table of Contents

Advertisement

Available languages

Available languages

5.5.1

Wiring of motor temperature monitoring

The drive controller features 2 connections for motor temperature monitoring:
Terminals T1, T2 for connecting a PTC thermistor or thermal contact (NC contact).
ƒ
Pin X8/5 and X8/8 of the incremental encoder input (X8) for connecting a KTY
ƒ
thermal sensor.
Connectable thermal
sensor
Tripping point
Notes
Connection to incremental encoder input (X8)
)
Note!
Lenze system cables for motor feedback include additional cores for
temperature feedback. The cables are designed for wiring according to EMC.
Fig. 5−13
EDKVF9383 DE/EN/FR 4.0
Wiring of motor temperature monitoring
Incremental encoder input (X8)
Linear thermal sensor (KTY)
l
Warning: Adjustable
l
Error (TRIP): Fixed at 150 °C
l
Monitoring is not active in the Lenze
setting.
l
The KTY is monitored with regard to
interruption and short circuit.
V
CC5 _ E
GND
KTY
+KTY
-KTY
Connection to incremental encoder input (X8)
X8/5, X8/8
Connection of KTY thermal sensor
l
Electrical installation
Motor connection
Terminals T1, T2
l
PTC thermistor
– PTC thermistor with defined
l
Thermal contact (NC contact)
– Temperature switch as NC contact
l
Fixed, (depending on the PTC/thermal
contact)
l
PTC: R
l
Configurable as warning or error
(TRIP)
l
Monitoring is not active in the Lenze
setting.
l
If you do not use a Lenze motor, we
recommend a PTC thermistor up to
150°C.
X8
B
B
1
A
2
A
3
4
5
Z
6
Z
7
8
9
operating temperature (to
DIN 44081 and DIN 44082)
J >
W
1600
9300VEC068
5
93