Basics For Wiring According To Emc; Shielding; Mains Connection, Dc Supply - Lenze 9300 Series System Manual

Vector
Hide thumbs Also See for 9300 Series:
Table of Contents

Advertisement

5.3

Basics for wiring according to EMC

5.3.1

Shielding

5.3.2

Mains connection, DC supply

EDSVF9383V EN 7.1−04/2012
The shielding quality is determined by a good shield connection:
ƒ Connect the shield with a surface as large as possible.
ƒ Use a conductive clamp to connect the shield to the conductive and
grounded mounting plate with a surface as large as possible.
ƒ Unshielded cable ends must always be as short as possible.
ƒ You can use unshielded single cores or unshielded cables to connect
the controller and the mains choke to the mains.
ƒ For DC−bus operation or DC supply, use shielded cables.
ƒ The cable cross−section must be dimensioned for the assigned fuse
protection (national and regional regulations).
l
Basics for wiring according to EMC
5.3
Shielding
5.3.1
5.3−1