R&S 4200 Series Operating Manual page 71

Table of Contents

Advertisement

Configuring with the R&S ZS 4200
TX Preemphasis
SNMP Community
String
SNMP Enable
E1 Alarm for Inactive
Warning
DC-Battery
Supervision
AC-Main
Supervision
VoIP radio URI RX
For the use especially with long telephone lines, the AF response shape
can be adjusted in a way that higher frequencies have higher gain than
lower frequencies. The value in dB specifies the gain at AF = 3400 Hz in
comparison to AF = 800 Hz. Nominal TX audio level is always related to
AF = 1 kHz. Default value is 0 dB which means that TX preemphasis is off.
Name of the SNMP communication community. It is used to restrict the
network access.
The parameter is used to enable and disable the SNMP functionality of the
radio on the LAN interface.
If the parameter is set to "Disable", the SNMP functionality is disabled and
only GB2PP protocol is supported via LAN. If the parameter is set to
"Enable", both GB2PP and SNMP protocols are supported.
Note: It is strongly recommended to disable the SNMP protocol if only the
GB2PP protocol is used.
The parameter is used to enable/disable the transfer of the inactive
warning via the E1 interface.
The voltage during battery operation can be monitored. If the voltage is too
low, two responses in the radio can be triggered.
The Warning setting generates the CBIT warnings 0301 and 0401, which
are output via the remote system connected.
The
NOGO
setting
(connector X5.4) and initiates a switchover to the standby mode in
a main/standby configuration. This setting is recommended if, for example,
two separate DC networks are used for the main and standby radios.
The voltage during network operation can be monitored. If the voltage is
too low, two responses in the radio can be triggered:
The warning setting generates the CBIT warnings 0302 and 0402, which
are output via the remote system connected.
The
NOGO
setting
(connector X5.4) and initiates a switchover to the standby mode in
a main/standby configuration. This setting is recommended if, for example,
two separate AC networks are used for the main and standby radios.
Note: If the AC-Mains fail, operation automatically switches to the standby
radio. Otherwise the DC battery of the main radio would be
unnecessarily discharged.
This is the unified identifier for VoIP communication of the RX module. This
identifier
consists
of
user@<IP Address>
user@muenchen.rohde-schwarz.de.
The URI can be up to 64 characters. Characters and other naming
conventions have to follow the RFC 3986 rules. Using the reserved
characters makes the URI invalid and thus the VoIP operation is not
possible.
The default value of URI RX module is rx@192.168.52.101.
3.19
sets
the
TEST_OC
sets
the
TEST_OC
two
parts
concluded
or
user@<Full Qualified Domain Name>
R&S XU 4200
signal
at
the
output
signal
at
the
output
with
the
"@"
sign
eg.
6166.5368.02.01