Dc Input/Battery Input X2; Fig. 6.2 Dc Input/Battery Input X2 - R&S 4200 Series Operating Manual

Table of Contents

Advertisement

R&S XU 4200
6.2.2

DC Input/Battery Input X2

XLR connector type
Entry in column D (direction): O = Output
Entry in column T (type):
Signal description
Battery
GND
N.C.
Common Antenna X3\Common Antenna X3 "Radio".doc
6166.5368.02.01
Fig. 6.2
DC input/battery input X2.
I = Input
A = Analog
D = Digital
D T
Range
I
P
19 to 32 V DC
max. 16 A
I
P
(if an external device
is connected to X5.6,
X7.1/X7.2, X10.6 and
X11.1/ X11.2)
– – –
1
3
2
B = Bi-directional
P = Power
Contact
X2.1
X2.2
X2.3
6.2
Interface Description
Remarks
Positive battery contact
Negative battery contact
System ground
N. C.