Rx Cbit Events - R&S 4200 Series Operating Manual

Table of Contents

Advertisement

R&S XU 4200
4.2.2

RX CBIT Events

Code
Message
0101
INACTIVE WARNING
0102
NOGO ERROR
0103
MAIN FAN WARNING
0104
MAIN FAN ERROR
0107
MMI WD Restart
0109
MODE IMPOSSIBLE
6166.5368.02.01
Level Config
W
W
Radio was switched to
the inactive mode, e.g.
via the *OFF contact on
the rear panel or by
software command or
locally on the radio (see
chapter 3.4.7.2).
Note: If the radio
switches into INACTIVE
mode, all active VoIP
connections will be
terminated and new
VoIP connection
requests will be
E
Radio switches to the
NOGO state.
The NOGO error is the
general fault in the
radio and corresponds
to the GO LED. At least
one error or one NOGO
warning exists.
W
N
Rotation speed of the
main fan is low.
E
Main fan is not running
or is blocked.
W
Indication of restart
after the watch-dog
timer expires.
W
Operating modes of the
receiver module and
transmitter module do
not fit together or mode
setting failed.
4.16
Note
Check the VOP LED (see
Check the hardware
input *OFF on connector
Check software settings.
rejected.
Check the NOGO
configuration via service
PC (see chapter 3.3).
Analyze the CBIT status
in detail in order to find
out what the fault actually
Check airflow of fans and
clear the ventilation
Check the internal
temperatures in the radio
(see chapter 3.4.7.4.3) to
determine whether
operation can be
maintained for a certain
time (see chapter 5.2).
If this fails to eliminate
the fault, send the radio
Send the radio to service.
This maybe a software
error. Please report it to
the service. Radio will be
restarted automatically.
Please retry to setup the
modes. If this fails to
eliminate the problem,
this might be a software
error. Please report it to
Troubleshooting
Action
chapter 4.1.2).
X10.7.
is.
opening.
to service.
the service.