Ocxo Adjustment (Optional); Fig. 5.2 Test Connection Of Ocxo Adjustment - R&S 4200 Series Operating Manual

Table of Contents

Advertisement

R&S XU 4200
5.1.2

OCXO Adjustment (Optional)

OCXO adjustment
6166.5368.02.01
Due to the natural aging of the crystal oscillator (OCXO), it is advisable to
check the frequency offset after the first year of operation and readjust it if
necessary. We recommend a further adjustment interval of 3 years in order
to ensure the specified frequency accuracy.
Note: If the radio is started at low temperatures (approximately −20 °C),
the frequency of the OCXO is far from its nominal value. This causes the
generation of the CBIT message 0315 TX INT REF UNLOCK. When the
OCXO is warmed up, this message will disappear. This is a typical behavior
of radios with the OCXO installed and not an indication of a radio failure.
Test connection
D.U.T.
Fig. 5.2
Test procedure
DUT is controlled via the R&S ZS 4200 (see chapter 3.3).
The minimum warm-up time is 10 minutes for the OCXO. The OCXO
OVEN WARNING must disappear before the OCXO can be adjusted.
Test frequency:
Power level set:
Mode:
Radio is keyed ON, e.g. via function Test PTT, which delivers an
unmodulated CW signal (see chapter 3.4.7.4.1).
Measure frequency at antenna X3 and adjust OCXO value using
the Service & Maintenance Tool R&S ZS 4200 (see chapter 3.3).
The step width (1 bit) for the adjustment is approximately 1.5 Hz.
Adjust it only in small steps and do not detune the OCXO to the
extreme positions, because the internal reference on the RF module
could unlock here (CBIT error 0108, see chapter 4.2.1).
Nominal value
OCXO Δf ≤ ±0.02 ppm (corresponds to ± 2.4 Hz at 120 MHz)
Scheduled Maintenance
ATT
X3
30 dB
Test connection of OCXO adjustment.
120 MHz (see chapter 3.4.7.2)
Low (see chapter 3.4.7.2)
AM (see chapter 3.4.7.2)
5.2
Spectrum
analyzer/
frequency
counter

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xu 4200

Table of Contents