Display Of The Current Charge Level; Preparation For Use; Alignment; Shortening The Tube Adapter - Otto Bock Kenevo 3C60 Instructions For Use Manual

Hide thumbs Also See for Kenevo 3C60:
Table of Contents

Advertisement

Indication of the charging process:
Charger
Battery is charging.
The on time of the LED indicates the current battery charge level.
The on time of the LED gets longer as the charge level increases. It only flashes briefly at the start
of the charging process and stays on continuously at the end of the charging process.
Battery is fully charged, or the temperature fell above/below the permissible range during charging.
Check current charge level (see Page 19).

6.3 Display of the current charge level

Beep signal
5x short
4x short
3x short
2x short
1x short
1x short

7 Preparation for use

7.1 Alignment

The following alignment guidelines contain descriptions for connecting the knee joint to a prosthetic socket. In
principle, the alignment of the prosthesis is independent of the type of connection for the knee joint. In case of a
connection to an osseointegrated, percutaneous implant system, a socket is not used during bench alignment in
the alignment apparatus. In this case, the central proximal point on the prosthetic socket corresponds to the
trochanter of the thigh bone (see illustration in the section "Bench alignment in the alignment apparatus" see
Page 20).
Ensure that possible flexion or adduction of the transfemoral residual limb can be compensated to a permissible
extent by an adapter approved by the implant manufacturer in the course of static alignment optimisation. Safe
functioning of the knee joint is only guaranteed with biomechanically correct alignment.

7.1.1 Shortening the Tube Adapter

CAUTION
Incorrect processing of tube
Falling due to damage to the tube.
► Do not clamp the tube into a vice.
► For shortening the tube, use only a tube cutter.
CAUTION
Damage to the cable while shortening the tube adapter
Falling due to unexpected product behaviour as the result of switching into safety mode.
► When shortening the tube adapter, make sure the cable does not get damaged.
Kenevo 3C60/3C60=ST
1) Turn the prosthesis 180° (the sole of the foot has to face up).
2) Hold still for 2 seconds and wait for beeps.
Vibration signal
3x long
5x long
Preparation for use
Battery charge level
more than 80%
66% to 80%
51% to 65%
36% to 50%
20% to 35%
less than 20%
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kenevo 3c60 st

Table of Contents