1 Foreword

INFORMATION
Date of last update: 2018-11-20
► Please read this document carefully before using the product.
► Instruct the user in the proper and safe use of the product.
► Please contact the manufacturer if you have questions about the product (e.g. regarding the start-up, use,
maintenance, unexpected operating behaviour or circumstances). Contact information can be found on the
back page.
► Please keep this document in a safe place.
The product "Kenevo 3C60/3C60=ST" is referred to as the product/prosthesis/knee joint below.
These instructions for use provide you with important information on the use, adaptation and handling of the
product.
Only put the product into use in accordance with the information contained in the accompanying documents sup­
plied.

2 Product description

2.1 Design

The product consists of the following components:

2.2 Function

This product features a microprocessor-controlled switch between the stance phase and swing phase and a micro­
processor-controlled stance phase.
The microprocessor uses the measurements of an integrated sensor system as a basis to control a hydraulic unit
that influences the damping behaviour of the product.
These sensor data are updated and evaluated 100 times per second. As a result, the behaviour of the product is
adapted to the current motion situation (gait phase) dynamically and in real time.
Thanks to the microprocessor-controlled stance phase, the system can be individually adapted to the needs of the
patient.
For this purpose, the product is configured with the "K-Soft" adjustment software.
Through the adjustment software, it is possible to choose from three activity modes that make the various functions
of the product available. This permits optimum adaptation of the product to the corresponding mobility grade of the
patient. The configured activity mode cannot be changed by the patient.
In case of a product malfunction, safety mode makes restricted operation possible. Resistance parameters that are
predefined by the product are configured for this purpose (see Page 31).
The microprocessor-controlled hydraulic unit offers the following advantages
Stability while standing and walking
Kenevo 3C60/3C60=ST
1. Proximal pyramid adapter
1
2. LED (blue) as indicator for the Bluetooth connec­
2
3. 8° flexion stops (already installed on delivery)
3
4. Battery and cover caps
4
5. Hydraulic unit
6. Receiver of the inductive charging unit
5
7. Distal tube clamp screw
8. Connecting cable for tube adapter
6
7
8