CAUTION
Use of the product when battery charge level is too low
Falling due to unexpected behaviour of the prosthesis because of changed damping behaviour.
► Check the current charge level before use and charge the prosthesis if required.
► Note that the operating time of the product may be reduced at low ambient temperatures or due to ageing of
the battery.
CAUTION
Risk of pinching in the joint flexion area
Injuries due to pinching of body parts.
► Ensure that fingers/body parts or soft tissue of the residual limb are not in this area when bending the joint.
CAUTION
Penetration of dirt and humidity into the product
>
Falling due to unexpected product behaviour as the result of a malfunction.
>
Falling due to breakage of load-bearing components.
► Ensure that solid particles, foreign objects and liquids (such as body and/or wound fluids) are not allowed to
penetrate into the product.
► Do not expose the product to splashed water.
► Thick clothing should be worn over the product as a minimum in rainy conditions.
► If water, salt water or body and/or wound fluid has penetrated the product and components, the Protective
Cover (if any) must be removed immediately. Dry the knee joint and components with a lint-free cloth and
allow the components to fully air dry. The prosthesis must be inspected by an authorised Ottobock Service
Centre.
CAUTION
Mechanical stress during transport
>
Falling due to unexpected product behaviour as a result of a malfunction.
>
Falling due to breakage of load-bearing components.
>
Skin irritation due to defects on the hydraulic unit with leakage of liquid.
► Only use the transport packaging for transportation.
CAUTION
Signs of wear to the product components
Falling due to damage or malfunction of the product.
► In the interest of the patient's safety and in order to maintain operating reliability, the product must be ser­
viced at regular intervals.
NOTICE
Improper product care
Damage to the product due to the use of incorrect cleaning agents.
► Clean the product with a damp cloth only (fresh water).
INFORMATION
Knee joint movement noise
When using exoprosthetic knee joints, servomotor, hydraulic, pneumatic or brake load dependent control func­
tions can cause movement noise. This kind of noise is normal and unavoidable. It generally does not indicate any
problems. If movement noise increases noticeably during the lifecycle of the knee joint, the knee joint should be
inspected by an authorised Ottobock Service Centre immediately.