Products Covered by this Document

X-Series Processor and Disk Drive Configurations

X-Series Processor and Disk Drive Configurations
This document describes alternative Processor and Disk Drive Configurations
for X-Series analyzers. Due to continuous improvement of the X Series
Analyzer range, configurations may vary according to such factors as:
manufacturing date, product name, and installed options. Processor and disk
drive configurations are considered separately, due to the large number of
possible combinations.
The installed memory components, and the procedures for sanitization of the
instrument's memory, differ according to the processor and disk drive
configurations. Therefore, to identify the correct information and procedures for
your instrument, you need to determine its
and

Processor Assembly Configuration

There are several possible processor assembly configurations: older
configurations have a non-removable (fixed) disk drive, while newer
configurations have a removable disk drive. The relationship between
processor assembly type and product name is detailed in
details of how to determine installed options, see
Options" on page
Table 2-1
Processor Assembly & Product Name
Type
Configuration
1
Fixed Disk
2
Removable Disk
Security Features & Document of Volatility
Disk Drive
Configuration.
13)
Product Names & Installed Options
The disk is referred to as "fixed", because it can only be removed by removing
and opening the instrument's processor assembly.
This configuration is standard for:
a. MXA instruments without Option PC2, PC4 or PC6(S),
b. EXA instruments without Option PC2, PC3, PC4, PC5, PC6(S) or PC7(S),
c. CXA instruments without Option PC3, PC5 or PC7(S)
The disk may be removed from the instrument's rear panel, without removing
or opening the processor assembly.
This configuration is standard for:
a. All PXA instruments,
b. MXA instruments with Option PC2, PC4 or PC6(S),
c. EXA instruments with Option PC2, PC3, PC4, PC5, PC6(S) or PC7(S),
d. CXA instruments with Option PC3, PC5 or PC7(S)
Processor Assembly Configuration
Table 2-1
"Determining Installed
below. (For
8