Trouble Shooting - Siruba ASP-EBJ100 Instruction Book

Table of Contents

Advertisement

TROUBLE SHOOTING

Indicator
STOP ①
BAND ②
COUNTER ④
STOP ①
THREAD ③
STOP ①
BAND ②
Solution A1: To disarm Emergency
1. Release EMERGENCY stop ⑤ by rotating and pulling up.
2. Press RESET ⑧ to turn off indicator STOP ① .
3. Press START ⑨ to restart the work, or to resume the work from an interruption.
4. Pressing EMERGENCY stop ⑤ when:
4-1. Power ON, machine is in ready or stand-by situation. Follow step 1~3 to restart.
4-2. Band is circled and ready for sewing: Sewing interrupts and stops. Error code E5 shows on sewing machine
panel. Following step 1~2 and go to the sewing machine panel.
(1) Press R (RESET) ⑩ to cut the thread.
(2) Press R (RESET) ⑩ again to remove the defective band.
(3) Follow step 3 to resume the operation.
P14
Operation Panel
重疊量
LAPPING
SIZE
Status
Description
ON
EMERGENCY ⑤ pressed
1. Band runs out.
ON
2. Bad joint detected
1. Feeding malfunctions
Flashing
2. Problem other than devices, i.e. band falls off.
ON
Work reaches the setting target
Both
Sewing machine is not ready.
Flashing
Both
Limit Switch malfunctions
Flashing
Sewing Machine Operation Panel
⑭ ⑮
Solution
A1
A2
A3
A4
A5
A6
A7
A8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asp-ebj100s

Table of Contents