Trouble Shooting - Siruba ASK-ASM100 Instruction Book / Parts List

Table of Contents

Advertisement

TROUBLE SHOOTING

Mechanic or finished quality issue
Issue
Deformation:
Poor elasticity
Rippled cuff
Poor stitching line
Fabric accumulation:
Fabric overlapping
Bad fabric feeding
Abnormal sewing:
Sewing stops
before operation
completes.
Sewing cannot stop
Bad Cutting
Electronic Issues
Error Code
Cause
Err 1
Over Current
Err 4
Over Voltage
Cause
Stretching system over-
stretches.
Not enough stretching
distance
Angle error on Pulling Roller.
Aligning roller over-presses,
causing fabric jam
Poor contact of Feeding Roller
against the fabric
Cross-seam Sensor is too low,
any tiny ridge may taken as
operation completes.
Cross-seam sensor is too
high, cannot detect cross-
seam to end the operation.
Not enough reserved stitch
after ejection
Not enough stitch after
suction/cut
1. Turn off the power.
2. Check if the IGBT module is normal.
3. Reboot the system after 1 min.
4. If the error code still exits, please exchange control box and
contact Kaulin or authorized agents.
1. Turn off the power.
2. Check the power connection to the control box. Check if the
power supply complied to specification.
3. If the voltage is too high, please wait until the power is normal
and then reboot. If not, reboot the system after 1 minute.
4. If the error code still exits, please exchange control box and
contact Kaulin or authorized agents.
Solution
Adjust the stretching
system
Adjust the Roller angle
and contact area with
fabric.
Adjust the Roller angle
and contact area with
fabric.
Adjust the sensor of
cross-seam system.
Reset the parameter
#14、#18
Solution
Reference
Stretching System
Cross Seam System:
Pulling Roller
Aligning System
Cross-Seam System:
Cross-Seam Sensor
Parameter List:
Item #14、#18
P13