SERVICE & MAINTENANCE
A.Band & Band Feeder Position
1. Disconnect the air supply. Loosen the Screw ② to adjust the distance between Band Locator ① and Needle
Holder to be 4.5 ~ 5mm.
2. When the band reaches the presser foot, the inner side of the band should align with the Locator ① . Refer to
Testing Mode to verify the position. Check if there is a gap (less than 0.5mm) between the circled band and
locator ① .
3. When the Locator ① pressed and holds the band, the work will be pulled up, causing a breaking thread or poor
sewing. You may need to adjust the Band Feeder position.
4. To adjust the Band Feeder: Loosen 5 screws ③ . Move the Base ④ along with the Inductor ⑤ . After the
adjustment, tighten the 3 screws on the Base ④ . Fix the Rear Board ⑥ of the Band Feeder onto the Base ④
4.5~5mm
P17