Section 4 – Installing Supporting Furniture and Casework
4.10 Floor and Wall-Mounted
Cabinets
Adjusting Steel Hinged Doors:
1. When the hinged door is low or high in the opening
of the cabinet:
– Loosen the screws that hold the hinges to the
cabinet side.
– Raise or lower the door so the reveal is the same
width around the entire door.
– Tighten the screws on the hinges.
– Check and re-adjust if necessary.
2. When the hinged door is crooked or cocked in the
opening of the cabinet:
o
– Make a 90
angle bend 3" long using a piece of
heavy wire.
– With the door open, insert the 3" end between the
leaves of the top or bottom hinge.
– close the door slowly and the hinge will open,
moving the top or bottom of the door towards the
jamb – do not close the door all the way.
– Test the for proper alignment, repeat the above
steps if necessary until the door hangs straight.
Adjusting Steel sliding Doors:
Refer to Figure 4-22.
1. Hangers (A) can be left alone at this time.
50
(cont.)
Adjust this Hanger
(B)
(B)
This Gap
Figure 4-22 Adjusting Steel Sliding Doors
2. Use a flat blade screwdriver to turn the adjusting
disk (B).Clockwise rotation lowers the door and
counterclockwise rotation raises the door.
3. To make the doors plumb with the cabinet side,
adjust the doors to the full up or down position. If
the gap is very small, a slight adjustment of one
or both hangers may be sufficient.
When the doors are plumb with the cabinet side,
make the up and down adjustment of the door equal-
ly. Adjust both hangers to achieve proper clearance
at the bottom door guide (C).
Removing the framed glass or solid sliding doors:
1. Loosen the screws and remove the bottom door
guide.
2. Tilt the door to permit the top of the nylon roller to
move out of the track – do not force. If the door
binds or hangs up, adjust the rollers to provide
more space between the top of the door edge and
the track.
3. Repeat the tilting procedure. Lift and remove the
door.
4. Repeat for the second door. It may be necessary
to remove and lean the lower shelf or shelves
against the cabinet back to provide clearance for
door movement.
5. Clean the glass and replace the doors. Replace
the back door first. Tilt the door to place the bot-
tom roller into the track. Move the door to a verti-
cal position and adjust to provide clearance for
the guide.
6. Repeat the above procedure for the front door.
7. Replace the bottom door guide.