Section 3 – Installing Wall Frames
3.7

Base Molding

Tools Required:
9/16" Wrench
1/2 Wrench
Procedure:
Refer to Figure 3-13:
Floor Clamp
Figure 3-13 Base Molding
1. Loosen the anchor bolts on the floor clamps.
Note: On new installations, locate the floor clamp,
drill a hole for the anchor and insert the anchor. Next,
insert the floor angle and securely tighten the anchor
bolts.
2. Slide the floor angle between the floor and the
floor clamp. Adjust the floor angle so the vertical
flange is flush with the front surface of the risers.
Use appropriate anchors or adhesive to secure
the angle to the floor.
3. Attach the base molding to the floor angle.
Base Molding