Chapter 4 Operation and Control

mA-3011 Network Configuration

Network Configuration
mA-3011

Network Connection Options

NOTE
To ensure proper sequencing, connect network cables to the Chassis and mA-3011
before powering on the Chassis. AXIe Chassis identify installed modules and network
connections during the start up process; if network connections are changed after the
Chassis has been powered on the Chassis will be unable to locate and identify the
network connections. If network connections need to be changed, power down the
Chassis before reconfiguring the network connections.
The recommended LAN connections are as follows:
Chassis Rear Panel Ethernet Connector: Use to establish a wired network
connection (refer to the mA-1302/mA-1305 AXIe Chassis Operation Manual).
mA-3011 GbE Connector: Use to connect Chassis to peripheral equipment

Network Settings

This section contains instructions to connect to the mA-3011 via a network connection.
DEFAULT STATIC IP NOTICE
The module ships from the factory with an assigned Static IP Address. Do not connect
the module to your local area network (LAN) without contacting your IT department to
determine if the module's default IP Address is already in use. If the module's default
IP Address is already in use by a device on the network, connecting the module to the
network will cause a network conflict.
It is recommended that the module be reconfigured to use a Static IP address
assigned by your IT department before connecting the device to a LAN.

mA-3011 Default IP Address

The mA-3011's IP Address is needed to access the module using external user interface
tools and software applications. In the event the module's IP Address has been changed,
see the section below ("Locate mA-3011 IP Address")
The mA-3011 default IP Address is: 10.105.8.34
NOTE - DUAL SYSTEMS
When a Dual mA-3011 modules is received from the factory, the default IP address of
the second CPU processor is 10.105.8.33.
Page 4-4
mA-3011 AXIe Embedded Host Module Operation Guide
Rev. C0
May 2020