1. Assembly and Ink Filling
IMPORTANT
When you remove the drain bottle, a few drops of discharged fluid may come out of the drain funnel. Exercise
caution to prevent this fluid from soiling your hands or the floor.
CAUTION
WARNING
CAUTION
E
Quickly attach the emptied drain bottle to the machine once more.
F
Press [ENTER].
When the screen shown in the figure appears, filling with ink is finished.
SETUP SHEET

Step 10: Adjustment of Media Holder Adjuster

This work requires subtle adjustments. Leave this work to a suitably qualified worker.
Items Used in this Procedure
General tools
(brought to the
work area by the
worker)
Included items,
retainer
50
2.Installation
Before you detach the drain bottle, be sure to wait for the screen to display
"EMPTY DRAIN BOTTLE." After discarding the discharged fluid, promptly attach
the drain bottle to the machine.
Failing to follow this procedure may cause discharged fluid to flow out of the tube
and spill, soiling your hands or the floor.
Never place discharged fluid or ink near an open flame.
Doing so may cause fire.
To store discharged fluid temporarily, place it in the included drain bottle or in a
durable sealed container such as a metal can or polyethylene tank, and cap the
container tightly.
Any spillage or vapor leakage may cause fire, odor, or physical distress.
6.0 mm (0.24 in.) hexagonal wrench
Masking tape
Scale (ruler)
Paper tube (1)
Adjustment papers (2)
Retainer B (1)
 P. 41 "Step 5: Removing the Retainers"
"