Communication specifications
Item
Protocol
Transmission medium
Transmission speed
Transmission method
Fieldbus protocol
Vendor ID
Product type
Product code
Network topology
Applicable function
IP address setting range
Configuration file
Occupied area
(number of inputs/outputs)
Connectable valve series
Valve Series
JSY series
SY series
VQC series
Ethernet (IEEE802.3)
Standard Ethernet cable (CAT5 or more)
(100BASE-TX)
10 Mbps/100 Mbps (Auto negotiation)
Full duplex/Half duplex (Auto negotiation)
TM
EtherNet/IP
Volume1 (Edition 3.25)
Volume2 (Edition 1.23)
7h (SMC Corporation)
1Bh (Pneumatic Valve)
F9h
Star: Applicable
Linear Bus: Applicable
Ring (including DLR): Applicable
TM
QuickConnect
DLR (Device Level Ring)
Manual setting using switches in SI unit: 192.168.0.1 to 254 or 192.168.1.1 to 254
Via DHCP server: Arbitrary address
ex260_sen2_x205_24_v**.eds
16/32
JSY1000, JSY3000, JSY5000
SY3000, SY5000, SY7000
VQC1000, VQC2000, VQC4000, VQC5000
-44-
Specifications
No.EX※※-OMX1001
Need help?
Do you have a question about the EX260-SEN2-X205 and is the answer not in the manual?