Orion
Revision 3.1
21 May 2020
Orion Carriage Multistretch Settings Screen
Figure 3 - 30
The Orion Carriage
Multistretch Screen
Table 3-26. The Orion Carriage Multistretch Screen Button Descriptions
STATE 1
ZERO TRIM
GAIN
SENSOR (MA) VALUE
MODIFY SETTINGS
APPLY SETTINGS
TENSION UP %
TENSION DOWN %
This is the Multistretch Settings screen. This page is useful primarily to repair personnel
when troubleshooting the machine.
Press this button to modify the Zero Trim datapoint, in terms of milliamps. This
value determines at which point the Multistretch will begin paying out film as the
dancer bar is deflected. This value should be .5 mA higher than the Hall Effect Sen-
sor reading with the dancer bar at rest. Min - 3.mA Max - 8 mA
Press this button to modify the Gain datapoint, in terms of percentage. This value
sets percentage of deflection of the dancer bar that is required for the Multistretch to
pay out film at maximum speed. Min - 10% Max - 100%
This displays the current dancer bar Hall Effect Sensor reading, in terms of milli-
amps.
Press this button for access to modify the Zero Trim or Gain datapoints.
The Multistretch is disabled while modifying the datapoints.
Press this button to accept the current Zero Trim and Gain datapoints and apply
them to the Multistretch. When complete, the drive will be enabled again.
Press this button to enter the film tension percentage from 0-100% while the car-
riage is traveling up.
Press this button to enter the film tension percentage from 0-100% while the car-
riage is traveling down.
Sentry HP/ LP Flex Stretchwrapper
DESCRIPTION
Machine Manual
System Operation
Page 3-35