Alarm Displays - Pro Mach ORION Sentry HP Manual

Stretchwrapper
Table of Contents

Advertisement

Orion
Revision 3.1
21 May 2020

Alarm Displays

Note:
MESSAGE
NO CONTROL POWER
CARRIAGE GATE
OPEN DURING CYCLE
END OF ROLL OR
BROKEN FILM
CARRIAGE MOVING
UP TOO SLOWLY
CARRIAGE MOVING
DOWN TOO SLOWLY
CARRIAGE DOOR
OPEN
OBSTACLE DETECTED
The messages in this section are the various critical status messages. For non-critical
alarms, see "Message Displays" on page 3 - 49.
Correct the condition and press the Fault Reset button to clear the message and continue
machine operation. A description of these messages appears on the following pages.
Not all messages in this list are applicable to your machine. The
alarm messages on you machine may vary based on machine
options.
Table 3-37. The Information and Alarm Displays
DESCRIPTION
Control Power is not present.
The carriage gate opened during the cycle.
The film has broken or the roll ran out.
The carriage is moving upward too slowly.
The carriage is moving downward too slowly.
The carriage door is currently open.
The tower has an obstruction.
Machine Manual
Sentry HP/ LP Flex Stretchwrapper
System Operation
CORRECTION
Press the Control Power reset
button prior to starting the
machine.
Check for the cause of the
unlatch. Re-latch and restart,
when ready.
Re-load a new roll if out. If bro-
ken, monitor the film. Replace
roll if problem persists. See trou-
bleshooting chart for broken film
troubleshooting tips.
Check for the cause of the car-
riage not moving correctly.
Check the belt drive behind the
back panel. Check for a jam or
obstruction on the track.
Check for the cause of the car-
riage not moving correctly.
Check the belt drive behind the
back panel. Check for a jam or
obstruction on the track.
Close the carriage door to allow
operation.
Check for something under the
film carriage.
Check for a mechanical bind.
Reset and restart, when ready.