Table 3-36. The Information and Alarm Displays (Continued)
MESSAGE
FAULTS EXIST
CARRIAGE MOVING
UP TOO SLOWLY
CARRIAGE MOVING
DOWN TOO SLOWLY
MULTISTRETCH VFD
NOT READY
MAIN DRIVE VFD NOT
READY
CARRIAGE VFD NOT
READY
DOWNLOADING VFD
PARAMETERS -
PLEASE WAIT
X2X
COMMUNICATION
FAULT - PRESS E-STOP
TO CLEAR FAULT
RS485
COMMUNICATION
FAULT - PRESS E-STOP
TO CLEAR FAULT
DESCRIPTION
Faults currently exist.
The carriage is moving upward too slowly.
The carriage is moving downward too slowly.
The indicated VFD is not ready to run.
The VFD parameters are transferring to the
VFD's from the PLC.
There is an X2X communication fault, press and
release the E-stop button to clear the fault.
There is an RS485 communication fault, press
and release the E-stop button to clear the fault.
Machine Manual
Sentry HP/ LP Flex Stretchwrapper
System Operation
CORRECTION
Correct the cause of the fault.
Press reset to reset the fault con-
dition once the cause is cor-
rected.
Check for the cause of the car-
riage not moving correctly.
Check the belt drive behind the
back panel. Check for a jam or
obstruction on the track.
Check for the cause of the car-
riage not moving correctly.
Check the belt drive behind the
back panel. Check for a jam or
obstruction on the track.
Check the fault code on the VFD
display in the electrical cabinet.
See VFD manual for fault code
information.
Wait until the process is com-
pleted.
Contact Orion Packaging if
problem persists.
Contact Orion Packaging if
problem persists.
Page 3-51